Coming next · in build now

Charts that know which gauge took every reading.

Samples at the station, X-bar and range charts with fixed limits, a reaction plan when the process changes, and the lots to recheck when a gauge fails its calibration. Built on GageMakkal.

Out of control,but every part is good? The insert is wearing.Change it, then sample.
Makkal AIAI already reads calibration certificates in GageMakkal.Every app shares the same rule: AI prepares, a person decides.See Makkal AI →
Prototype: the screens below come from the SPCMakkal prototype, with made-up data. SPCMakkal is being built now; tell us about your characteristics and we will set it up with you.
01

At the station: the right gauge, the right person

  • Operators see only the characteristics they are qualified to record.
  • The gauge is scanned first: an overdue or "Do not use" gauge is blocked, straight from GageMakkal.
  • A gauge in keyboard mode types each value; nothing is sent until the sample is saved.
At the station: what is due, and taking a sample
At the station: what is due, and taking a sample
02

Control charts with fixed limits

  • X-bar and range charts against limits fixed from the first 25 subgroups, kept as versions.
  • A run chart against the tolerance beside it: "is this part good?" and "has the process changed?" are different questions.
  • Rule breaks and capability (Cp, Cpk) on every characteristic; samples due in windows, on time, late or missed.
A characteristic: X-bar chart, capability and the latest signal
A characteristic: X-bar chart, capability and the latest signal
03

A reaction when the process changes

  • An out-of-control point sounds at the station and waits for "I'm on it" before the next sample.
  • The control plan's steps, ticked one by one, then the cause and the outcome.
  • Every reaction kept with its sample, so the next audit sees what was done.
A reaction: the control plan's steps, the cause and the outcome
A reaction: the control plan's steps, the cause and the outcome
04

When a gauge fails its calibration

  • Each sample keeps the gauge used and its calibration status that day.
  • A failed gauge lists every lot it measured since its last good calibration, corrected by its error.
  • For each lot: recheck, assess with the customer, or it stays inside even when corrected.
A failed gauge: every lot it measured since its last good calibration
A failed gauge: every lot it measured since its last good calibration
Lathe L-3, Tuesday night

The insert is wearing. The chart says so before any part is bad.

  1. SampleTomás scans the micrometer, and its five readings go in from the gauge.
  2. SignalThe average crosses the control limit while every part is still in tolerance. The station sounds.
  3. ReactPiotr acknowledges, follows the control plan, changes the insert, and the next sample is back in control.
Out of control,but all parts are good. The insert is wearing.Changed. Sample again.
Works with

Better with the rest of the honeycomb.

GageMakkal checks every gauge before a sample. Later, CapaMakkal takes a reaction to a corrective action and SkillMakkal says who is qualified.

Talk to us early

Shape SPCMakkal before it opens.

SPCMakkal is being built now, with plants like yours. Tell us how you work today and what gets in the way.

  • A person answers within one working day, not a bot.
  • We show you the prototype on a call, with examples from your plant.
  • Early plants decide what comes first, and get it first.
What would you like?

We use your details only to answer you. No newsletter unless you ask.

Put your first characteristic on a chart.

Only want one email when it opens? Leave your address.

One email when SPCMakkal opens. Nothing else.